How To Install Led Flood Light

2022-07-14

Flood lights Installation Method: 


1. Preparation

Any kind of lighting installation requires preparation work, such as the tools to be used in the installation process, and to determine the location of the installation, and whether there is any damage to the floodlight product and its components. At the same time, the installer should read the installation manual of the floodlight in detail, and have a general understanding of the various steps in the installation process.


2、Floodlight installation

Depending on the place of use, there are wall mounted, pedestal, ceiling and other types of installation of the floodlight. Users can use screws to fix the floodlight to the wall according to their actual use of the occasion, but it should be noted that, to avoid the risk of falling in the future, make sure the lamp is firm.


3. Connecting wires

Here is a detailed introduction to the wiring method of the floodlight. Usually, led flood lights out of the three lines, which blue first and brown line were connected to the fire line and zero line, regardless of polarity. In addition, there is a yellow wire, yellow with a hint of green in the middle, also known as yellow green, this wire is grounded. The ground must be connected, the vast majority of floodlights are used outdoors, rain is difficult to avoid, so it is best to deal with the ground, to ensure the fundamental use of lighting safety.


4. Power on,  test light

When all the above work is done, you can turn on the power and see if the floodlight works properly. It is a good idea to use a multimeter to test the lamp on the main power supply to make sure there is no misconnection or short circuit before you turn it on. At the same time, after doing the test light work, keep observing the lamp for as long as possible to see if there is any abnormality.

 

Flood Light Installation Notes


1. The lamps and lanterns are designed for waterproof and moisture-proof, and their protection level can reach IP65, which can withstand rain from top to bottom but cannot be submerged underwater, and their protection level is not up to the requirements of underwater work.


2. The location where the light is installed must have a large enough bearing capacity, which should be able to bear 10 times the weight of the driver.


3. The working power of the lamps and lanterns is high-voltage alternating current, which should be away from the place where people can easily reach, and should be well grounded.


4. the lamps and lanterns are power type equipment, and very sensitive to the ambient temperature, the working environment temperature is higher than 45 ° C when its life will be significantly reduced, and accompanied by serious surface signs of light failure. Therefore, the lamp should be placed in a ventilated place, to keep the lamp has a relatively good heat environment conditions.


5. The working temperature of lamps and lanterns should be between -25 ° C ~ +45 ° C. The temperature of the workplace must not exceed 45 ° C. The lamp should be placed in a ventilated place. The temperature of the workplace must not exceed 45 ° C, in order to ensure the service life of the lamps and lanterns.


6. As the power of the lamp is relatively large, the power cord should be chosen according to the actual power of the power cord. And split-phase power supply.